1. POSITIONING of EQUIPMENT
- Ensure adequate airflow to machinery: not less than I Metre from a wall.
- Provide shade if possible from direct sun in summer.
2. POWER SUPPLY
- Connect to 32amp, 415v power outlet and tighten locking ring.
- 20amp outlet may not be suitable under extreme conditions.
3. POWER USAGE
- Approx 18amps on start up.
- Approx 8amps while running.
4. CLEANING COIL
- Monthly hose down or air clean of condenser to clean fins.
- Failure to clean will reduce performance, increase power use and eventually lead to failure.
5. MONITOR OPERATING TEMPERATURE
- Regularly check digital readout we can fit a dial thermometer in a prominent position if required.
6. HARD FROZEN OPERATION
- Load FROZEN product only. Do NOT load product at ambient temperature.
- Do NOT load product above RED LINE limit.
- Switch unit OFF before entering.
- If regular entry is required install a plastic strip curtain to contain internal temperature.
- At temp below minus 10deg C, unit will self regulate to maintain your set temperature.
7. CHILLER OPERATION
- Product can be loaded at ambient temperature.
- Do NOT load product above RED LINE limit.
- Switch unit OFF before entering.
- If regular entry is required install a plastic strip curtain to contain internal temperature.
- At chiller temperatures: + 2deg C to + 8deg C; the equipment will run continuously.
- At required temperature, the unit is in “Power Saver” mode, with fans running intermittently.
8. DEFROST CYCLE
- Can be set to 6, 9, 12, 24 hour intervals.( 9 is usual).
- Defrost cycle is to clear ice on evaporator coil and will function automatically.
9. ALARM CODES
- The equipment is self analysing.
- Many alarm codes can be re-set from “ over the phone “ instructions.
10. WARRANTY
- ANL Refrigerated Shipping Containers provides a 3 month warranty on equipment purchased for a period of 90 days from the date of delivery.
- The warranty is for parts and labour.(Conditions Apply).
11. SERVICE / MAINTENANCE CONTRACT
- A regular 3 monthly inspection / service is recommended to ensure continuing efficient and reliable operation of the equipment.
- All items are inspected: motors, fans, electronic calibration, defrost operation, gas level.
- We can arrange to establish a routine servicing agreement with our refrigeration engineer service provider.
|